/* Copyright (c) 1992-1997, Microsoft Corporation, all rights reserved ** ** raserror.h ** Remote Access external API ** RAS specific error codes */ #ifndef _RASERROR_H_ #define _RASERROR_H_ #define RASBASE 600 #define SUCCESS 0 #define PENDING (RASBASE+0) /* * An operation is pending.%0 */ #define ERROR_INVALID_PORT_HANDLE (RASBASE+1) /* * The port handle is invalid.%0 */ #define ERROR_PORT_ALREADY_OPEN (RASBASE+2) /* * The port is already open.%0 */ #define ERROR_BUFFER_TOO_SMALL (RASBASE+3) /* * Caller's buffer is too small.%0 */ #define ERROR_WRONG_INFO_SPECIFIED (RASBASE+4) /* * Wrong information specified.%0 */ #define ERROR_CANNOT_SET_PORT_INFO (RASBASE+5) /* * Cannot set port information.%0 */ #define ERROR_PORT_NOT_CONNECTED (RASBASE+6) /* * The port is not connected.%0 */ #define ERROR_EVENT_INVALID (RASBASE+7) /* * The event is invalid.%0 */ #define ERROR_DEVICE_DOES_NOT_EXIST (RASBASE+8) /* * The device does not exist.%0 */ #define ERROR_DEVICETYPE_DOES_NOT_EXIST (RASBASE+9) /* * The device type does not exist.%0 */ #define ERROR_BUFFER_INVALID (RASBASE+10) /* * The buffer is invalid.%0 */ #define ERROR_ROUTE_NOT_AVAILABLE (RASBASE+11) /* * The route is not available.%0 */ #define ERROR_ROUTE_NOT_ALLOCATED (RASBASE+12) /* * The route is not allocated.%0 */ #define ERROR_INVALID_COMPRESSION_SPECIFIED (RASBASE+13) /* * Invalid compression specified.%0 */ #define ERROR_OUT_OF_BUFFERS (RASBASE+14) /* * Out of buffers.%0 */ #define ERROR_PORT_NOT_FOUND (RASBASE+15) /* * The port was not found.%0 */ #define ERROR_ASYNC_REQUEST_PENDING (RASBASE+16) /* * An asynchronous request is pending.%0 */ #define ERROR_ALREADY_DISCONNECTING (RASBASE+17) /* * The port or device is already disconnecting.%0 */ #define ERROR_PORT_NOT_OPEN (RASBASE+18) /* * The port is not open.%0 */ #define ERROR_PORT_DISCONNECTED (RASBASE+19) /* * The port is disconnected.%0 */ #define ERROR_NO_ENDPOINTS (RASBASE+20) /* * There are no endpoints.%0 */ #define ERROR_CANNOT_OPEN_PHONEBOOK (RASBASE+21) /* * Cannot open the phone book file.%0 */ #define ERROR_CANNOT_LOAD_PHONEBOOK (RASBASE+22) /* * Cannot load the phone book file.%0 */ #define ERROR_CANNOT_FIND_PHONEBOOK_ENTRY (RASBASE+23) /* * Cannot find the phone book entry.%0 */ #define ERROR_CANNOT_WRITE_PHONEBOOK (RASBASE+24) /* * Cannot write the phone book file.%0 */ #define ERROR_CORRUPT_PHONEBOOK (RASBASE+25) /* * Invalid information found in the phone book file.%0 */ #define ERROR_CANNOT_LOAD_STRING (RASBASE+26) /* * Cannot load a string.%0 */ #define ERROR_KEY_NOT_FOUND (RASBASE+27) /* * Cannot find key.%0 */ #define ERROR_DISCONNECTION (RASBASE+28) /* * The port was disconnected.%0 */ #define ERROR_REMOTE_DISCONNECTION (RASBASE+29) /* * The data link was terminated by the remote machine.%0 */ #define ERROR_HARDWARE_FAILURE (RASBASE+30) /* * The port was disconnected due to hardware failure.%0 */ #define ERROR_USER_DISCONNECTION (RASBASE+31) /* * The port was disconnected by the user.%0 */ #define ERROR_INVALID_SIZE (RASBASE+32) /* * The structure size is incorrect.%0 */ #define ERROR_PORT_NOT_AVAILABLE (RASBASE+33) /* * The port is already in use or is not configured for Remote Access dial out.%0 */ #define ERROR_CANNOT_PROJECT_CLIENT (RASBASE+34) /* * Cannot register your computer on on the remote network.%0 */ #define ERROR_UNKNOWN (RASBASE+35) /* * Unknown error.%0 */ #define ERROR_WRONG_DEVICE_ATTACHED (RASBASE+36) /* * The wrong device is attached to the port.%0 */ #define ERROR_BAD_STRING (RASBASE+37) /* * The string could not be converted.%0 */ #define ERROR_REQUEST_TIMEOUT (RASBASE+38) /* * The request has timed out.%0 */ #define ERROR_CANNOT_GET_LANA (RASBASE+39) /* * No asynchronous net available.%0 */ #define ERROR_NETBIOS_ERROR (RASBASE+40) /* * A NetBIOS error has occurred.%0 */ #define ERROR_SERVER_OUT_OF_RESOURCES (RASBASE+41) /* * The server cannot allocate NetBIOS resources needed to support the client.%0 */ #define ERROR_NAME_EXISTS_ON_NET (RASBASE+42) /* * One of your NetBIOS names is already registered on the remote network.%0 */ #define ERROR_SERVER_GENERAL_NET_FAILURE (RASBASE+43) /* * A network adapter at the server failed.%0 */ #define WARNING_MSG_ALIAS_NOT_ADDED (RASBASE+44) /* * You will not receive network message popups.%0 */ #define ERROR_AUTH_INTERNAL (RASBASE+45) /* * Internal authentication error.%0 */ #define ERROR_RESTRICTED_LOGON_HOURS (RASBASE+46) /* * The account is not permitted to logon at this time of day.%0 */ #define ERROR_ACCT_DISABLED (RASBASE+47) /* * The account is disabled.%0 */ #define ERROR_PASSWD_EXPIRED (RASBASE+48) /* * The password has expired.%0 */ #define ERROR_NO_DIALIN_PERMISSION (RASBASE+49) /* * The account does not have Remote Access permission.%0 */ #define ERROR_SERVER_NOT_RESPONDING (RASBASE+50) /* * The Remote Access server is not responding.%0 */ #define ERROR_FROM_DEVICE (RASBASE+51) /* * Your modem (or other connecting device) has reported an error.%0 */ #define ERROR_UNRECOGNIZED_RESPONSE (RASBASE+52) /* * Unrecognized response from the device.%0 */ #define ERROR_MACRO_NOT_FOUND (RASBASE+53) /* * A macro required by the device was not found in the device .INF file section.%0 */ #define ERROR_MACRO_NOT_DEFINED (RASBASE+54) /* * A command or response in the device .INF file section refers to an undefined macro.%0 */ #define ERROR_MESSAGE_MACRO_NOT_FOUND (RASBASE+55) /* * The macro was not found in the device .INF file secion.%0 */ #define ERROR_DEFAULTOFF_MACRO_NOT_FOUND (RASBASE+56) /* * The macro in the device .INF file section contains an undefined macro.%0 */ #define ERROR_FILE_COULD_NOT_BE_OPENED (RASBASE+57) /* * The device .INF file could not be opened.%0 */ #define ERROR_DEVICENAME_TOO_LONG (RASBASE+58) /* * The device name in the device .INF or media .INI file is too long.%0 */ #define ERROR_DEVICENAME_NOT_FOUND (RASBASE+59) /* * The media .INI file refers to an unknown device name.%0 */ #define ERROR_NO_RESPONSES (RASBASE+60) /* * The device .INF file contains no responses for the command.%0 */ #define ERROR_NO_COMMAND_FOUND (RASBASE+61) /* * The device .INF file is missing a command.%0 */ #define ERROR_WRONG_KEY_SPECIFIED (RASBASE+62) /* * Attempted to set a macro not listed in device .INF file section.%0 */ #define ERROR_UNKNOWN_DEVICE_TYPE (RASBASE+63) /* * The media .INI file refers to an unknown device type.%0 */ #define ERROR_ALLOCATING_MEMORY (RASBASE+64) /* * Cannot allocate memory.%0 */ #define ERROR_PORT_NOT_CONFIGURED (RASBASE+65) /* * The port is not configured for Remote Access.%0 */ #define ERROR_DEVICE_NOT_READY (RASBASE+66) /* * Your modem (or other connecting device) is not functioning.%0 */ #define ERROR_READING_INI_FILE (RASBASE+67) /* * Cannot read the media .INI file.%0 */ #define ERROR_NO_CONNECTION (RASBASE+68) /* * The connection dropped.%0 */ #define ERROR_BAD_USAGE_IN_INI_FILE (RASBASE+69) /* * The usage parameter in the media .INI file is invalid.%0 */ #define ERROR_READING_SECTIONNAME (RASBASE+70) /* * Cannot read the section name from the media .INI file.%0 */ #define ERROR_READING_DEVICETYPE (RASBASE+71) /* * Cannot read the device type from the media .INI file.%0 */ #define ERROR_READING_DEVICENAME (RASBASE+72) /* * Cannot read the device name from the media .INI file.%0 */ #define ERROR_READING_USAGE (RASBASE+73) /* * Cannot read the usage from the media .INI file.%0 */ #define ERROR_READING_MAXCONNECTBPS (RASBASE+74) /* * Cannot read the maximum connection BPS rate from the media .INI file.%0 */ #define ERROR_READING_MAXCARRIERBPS (RASBASE+75) /* * Cannot read the maximum carrier BPS rate from the media .INI file.%0 */ #define ERROR_LINE_BUSY (RASBASE+76) /* * The line is busy.%0 */ #define ERROR_VOICE_ANSWER (RASBASE+77) /* * A person answered instead of a modem.%0 */ #define ERROR_NO_ANSWER (RASBASE+78) /* * There is no answer.%0 */ #define ERROR_NO_CARRIER (RASBASE+79) /* * Cannot detect carrier.%0 */ #define ERROR_NO_DIALTONE (RASBASE+80) /* * There is no dial tone.%0 */ #define ERROR_IN_COMMAND (RASBASE+81) /* * General error reported by device.%0 */ #define ERROR_WRITING_SECTIONNAME (RASBASE+82) /* * ERROR_WRITING_SECTIONNAME%0 */ #define ERROR_WRITING_DEVICETYPE (RASBASE+83) /* * ERROR_WRITING_DEVICETYPE%0 */ #define ERROR_WRITING_DEVICENAME (RASBASE+84) /* * ERROR_WRITING_DEVICENAME%0 */ #define ERROR_WRITING_MAXCONNECTBPS (RASBASE+85) /* * ERROR_WRITING_MAXCONNECTBPS%0 */ #define ERROR_WRITING_MAXCARRIERBPS (RASBASE+86) /* * ERROR_WRITING_MAXCARRIERBPS%0 */ #define ERROR_WRITING_USAGE (RASBASE+87) /* * ERROR_WRITING_USAGE%0 */ #define ERROR_WRITING_DEFAULTOFF (RASBASE+88) /* * ERROR_WRITING_DEFAULTOFF%0 */ #define ERROR_READING_DEFAULTOFF (RASBASE+89) /* * ERROR_READING_DEFAULTOFF%0 */ #define ERROR_EMPTY_INI_FILE (RASBASE+90) /* * ERROR_EMPTY_INI_FILE%0 */ #define ERROR_AUTHENTICATION_FAILURE (RASBASE+91) /* * Access denied because username and/or password is invalid on the domain.%0 */ #define ERROR_PORT_OR_DEVICE (RASBASE+92) /* * Hardware failure in port or attached device.%0 */ #define ERROR_NOT_BINARY_MACRO (RASBASE+93) /* * ERROR_NOT_BINARY_MACRO%0 */ #define ERROR_DCB_NOT_FOUND (RASBASE+94) /* * ERROR_DCB_NOT_FOUND%0 */ #define ERROR_STATE_MACHINES_NOT_STARTED (RASBASE+95) /* * ERROR_STATE_MACHINES_NOT_STARTED%0 */ #define ERROR_STATE_MACHINES_ALREADY_STARTED (RASBASE+96) /* * ERROR_STATE_MACHINES_ALREADY_STARTED%0 */ #define ERROR_PARTIAL_RESPONSE_LOOPING (RASBASE+97) /* * ERROR_PARTIAL_RESPONSE_LOOPING%0 */ #define ERROR_UNKNOWN_RESPONSE_KEY (RASBASE+98) /* * A response keyname in the device .INF file is not in the expected format.%0 */ #define ERROR_RECV_BUF_FULL (RASBASE+99) /* * The device response caused buffer overflow.%0 */ #define ERROR_CMD_TOO_LONG (RASBASE+100) /* * The expanded command in the device .INF file is too long.%0 */ #define ERROR_UNSUPPORTED_BPS (RASBASE+101) /* * The device moved to a BPS rate not supported by the COM driver.%0 */ #define ERROR_UNEXPECTED_RESPONSE (RASBASE+102) /* * Device response received when none expected.%0 */ #define ERROR_INTERACTIVE_MODE (RASBASE+103) /* * The Application does not allow user interaction. The connection requires interaction with the user to complete successfully. %0 */ #define ERROR_BAD_CALLBACK_NUMBER (RASBASE+104) /* * ERROR_BAD_CALLBACK_NUMBER */ #define ERROR_INVALID_AUTH_STATE (RASBASE+105) /* * ERROR_INVALID_AUTH_STATE%0 */ #define ERROR_WRITING_INITBPS (RASBASE+106) /* * ERROR_WRITING_INITBPS%0 */ #define ERROR_X25_DIAGNOSTIC (RASBASE+107) /* * X.25 diagnostic indication.%0 */ #define ERROR_ACCT_EXPIRED (RASBASE+108) /* * The account has expired.%0 */ #define ERROR_CHANGING_PASSWORD (RASBASE+109) /* * Error changing password on domain. The password may be too short or may match a previously used password.%0 */ #define ERROR_OVERRUN (RASBASE+110) /* * Serial overrun errors were detected while communicating with your modem.%0 */ #define ERROR_RASMAN_CANNOT_INITIALIZE (RASBASE+111) /* * RasMan initialization failure. Check the event log.%0 */ #define ERROR_BIPLEX_PORT_NOT_AVAILABLE (RASBASE+112) /* * Biplex port initializing. Wait a few seconds and redial.%0 */ #define ERROR_NO_ACTIVE_ISDN_LINES (RASBASE+113) /* * No active ISDN lines are available.%0 */ #define ERROR_NO_ISDN_CHANNELS_AVAILABLE (RASBASE+114) /* * No ISDN channels are available to make the call.%0 */ #define ERROR_TOO_MANY_LINE_ERRORS (RASBASE+115) /* * Too many errors occurred because of poor phone line quality.%0 */ #define ERROR_IP_CONFIGURATION (RASBASE+116) /* * The Remote Access IP configuration is unusable.%0 */ #define ERROR_NO_IP_ADDRESSES (RASBASE+117) /* * No IP addresses are available in the static pool of Remote Access IP addresses.%0 */ #define ERROR_PPP_TIMEOUT (RASBASE+118) /* * Timed out waiting for a valid response from the remote PPP peer.%0 */ #define ERROR_PPP_REMOTE_TERMINATED (RASBASE+119) /* * PPP terminated by remote machine.%0 */ #define ERROR_PPP_NO_PROTOCOLS_CONFIGURED (RASBASE+120) /* * No PPP control protocols configured.%0 */ #define ERROR_PPP_NO_RESPONSE (RASBASE+121) /* * Remote PPP peer is not responding.%0 */ #define ERROR_PPP_INVALID_PACKET (RASBASE+122) /* * The PPP packet is invalid.%0 */ #define ERROR_PHONE_NUMBER_TOO_LONG (RASBASE+123) /* * The phone number including prefix and suffix is too long.%0 */ #define ERROR_IPXCP_NO_DIALOUT_CONFIGURED (RASBASE+124) /* * The IPX protocol cannot dial-out on the port because the machine is an IPX router.%0 */ #define ERROR_IPXCP_NO_DIALIN_CONFIGURED (RASBASE+125) /* * The IPX protocol cannot dial-in on the port because the IPX router is not installed.%0 */ #define ERROR_IPXCP_DIALOUT_ALREADY_ACTIVE (RASBASE+126) /* * The IPX protocol cannot be used for dial-out on more than one port at a time.%0 */ #define ERROR_ACCESSING_TCPCFGDLL (RASBASE+127) /* * Cannot access TCPCFG.DLL.%0 */ #define ERROR_NO_IP_RAS_ADAPTER (RASBASE+128) /* * Cannot find an IP adapter bound to Remote Access.%0 */ #define ERROR_SLIP_REQUIRES_IP (RASBASE+129) /* * SLIP cannot be used unless the IP protocol is installed.%0 */ #define ERROR_PROJECTION_NOT_COMPLETE (RASBASE+130) /* * Computer registration is not complete.%0 */ #define ERROR_PROTOCOL_NOT_CONFIGURED (RASBASE+131) /* * The protocol is not configured.%0 */ #define ERROR_PPP_NOT_CONVERGING (RASBASE+132) /* * The PPP negotiation is not converging.%0 */ #define ERROR_PPP_CP_REJECTED (RASBASE+133) /* * The PPP control protocol for this network protocol is not available on the server.%0 */ #define ERROR_PPP_LCP_TERMINATED (RASBASE+134) /* * The PPP link control protocol terminated.%0 */ #define ERROR_PPP_REQUIRED_ADDRESS_REJECTED (RASBASE+135) /* * The requested address was rejected by the server.%0 */ #define ERROR_PPP_NCP_TERMINATED (RASBASE+136) /* * The remote computer terminated the control protocol.%0 */ #define ERROR_PPP_LOOPBACK_DETECTED (RASBASE+137) /* * Loopback detected.%0 */ #define ERROR_PPP_NO_ADDRESS_ASSIGNED (RASBASE+138) /* * The server did not assign an address.%0 */ #define ERROR_CANNOT_USE_LOGON_CREDENTIALS (RASBASE+139) /* * The authentication protocol required by the remote server cannot use the Windows NT encrypted password. Redial, entering the password explicitly.%0 */ #define ERROR_TAPI_CONFIGURATION (RASBASE+140) /* * Invalid TAPI configuration.%0 */ #define ERROR_NO_LOCAL_ENCRYPTION (RASBASE+141) /* * The local computer does not support the required encryption type.%0 */ #define ERROR_NO_REMOTE_ENCRYPTION (RASBASE+142) /* * The remote computer does not support the required encryption type.%0 */ #define ERROR_REMOTE_REQUIRES_ENCRYPTION (RASBASE+143) /* * The remote computer requires encryption.%0 */ #define ERROR_IPXCP_NET_NUMBER_CONFLICT (RASBASE+144) /* * Cannot use the IPX network number assigned by remote server. Check the event log.%0 */ #define ERROR_INVALID_SMM (RASBASE+145) /* * ERROR_INVALID_SMM%0 */ #define ERROR_SMM_UNINITIALIZED (RASBASE+146) /* * ERROR_SMM_UNINITIALIZED%0 */ #define ERROR_NO_MAC_FOR_PORT (RASBASE+147) /* * ERROR_NO_MAC_FOR_PORT%0 */ #define ERROR_SMM_TIMEOUT (RASBASE+148) /* * ERROR_SMM_TIMEOUT%0 */ #define ERROR_BAD_PHONE_NUMBER (RASBASE+149) /* * ERROR_BAD_PHONE_NUMBER%0 */ #define ERROR_WRONG_MODULE (RASBASE+150) /* * ERROR_WRONG_MODULE%0 */ #define ERROR_INVALID_CALLBACK_NUMBER (RASBASE+151) /* * Invalid callback number. Only the characters 0 to 9, T, P, W, (, ), -, @, and space are allowed in the number.%0 */ #define ERROR_SCRIPT_SYNTAX (RASBASE+152) /* * A syntax error was encountered while processing a script.%0 */ #define ERROR_HANGUP_FAILED (RASBASE+153) /* * The connection could not be disconnected because it was created by the Multi-Protocol Router.%0 */ #define RASBASEEND (RASBASE+153) #endif // _RASERROR_H_